IMMERSION VACUUM CLEANER SYSTEM FOR HAZARDOUS LOCATIONS

 

THE ULTIMATE EXPLOSION PROOF/DUST IGNITION PROOF INTERCEPTOR BATH

IMMERSION VACUUM CLEANER SYSTEM FOR HAZARDOUS LOCATIONS

Meets the NFPA 484 Standard for Combustible Metals

 

Tiger-Vac is pleased to introduce its latest model designed for the neutralization of recovered combustible, conductive and explosive dusts into an Immersion Bath System. Our uniquely designed Baffled Mechanism insures that the recovered dusts become inert when mixed with the neutralizing liquid within the recovery tank. The entire vacuum cleaner can also be rendered inert when supplied with ARGON Gas. A Coalescing Filter Element (CFE) for moisture removal is located downstream, along with a HEPA Filter with an efficiency of 99.995% on 0.3 micron, to ensure that no bubbles or particulate air can escape the system. Turnkey System - all filters, as well as a complete tool kit, are included with the unit. A Conversion Kit is available to convert for wet and dry recovery.

When dealing with the recovery of combustible/conductive metal dusts such as: Aluminum, Magnesium and all other dusts classified as commercial alloys: these dusts can cause an exothermic reaction and more severe damage than other types of combustible dusts. Because of this our system complies with NFPA, NEC and OSHA standards set for combustible, conductive dusts and flammable gases locations - Class I - Groups C & D and Class II - Groups E, F and G.

Please note the following: NFPA 484 standard for Combustible Metals - Vacuum cleaning shall be used only if listed or approved for use with combustible aluminum dust. It also states -  Typical Precipitation Collector for portable dust producing equipment are acceptable. The reaction of water and aluminum produces Hydrogen. Hydrogen is extremely flammable and very easy to ignite. Do not use water in this case in the Immersion Bath System when recovering aluminum and many other commercial alloys.

Tiger-Vac sold its first vacuum cleaner in 1969. Having been in business for over 40 years, we have come to know our industry very well. Our customers demand a commitment to manufacturing and delivering quality vacuum cleaners that suit their various needs.

Being ISO 90001:2008 and CSA, ATEX, IECEx, NRTL (Nationally Recognized Testing Laboratory) worldwide certified, we have not only met these demands but exceeded them. We continuously strive to improve upon our existing products, as well as design new systems, to serve ever changing industries.

For more information please visit our website located at www.tiger-vac.com.

FUEL AND SOLVENT RECOVERY VACUUM CLEANERS WITH ACTIVATED CARBON FILTERS

At Tiger-Vac we feel that Safety Has No Compromise. With this being our ultimate goal we have designed a full line of vacuum cleaners dedicated for the recovery of Fuel and Solvents.

The Tiger-Vac Vacuum Cleaners for Fuel and Solvent Recovery are the most advanced in the industry for Aircraft Maintenance. These units are all constructed of stainless steel SAE 304 and equipped with identifying red and yellow bands  meets NFPA 30 Chapter 4 (Container and Portable Tank Storage). They are available in both electrically or pneumatically (air) operated versions. Turnkey System  a Liquid Filter, as well as a De-Fueling Suction Hose, are included with the unit. Other tools and accessories for recovering spills off of the floor are also available.

When Fuel or Solvents are recovered, the vapors that are emitted from the Exhaust Port (downstream) of the vacuum cleaner must be evacuated or neutralized. There are two options to be considered in order to avoid vapor emissions being spread into the atmosphere and creating an explosive environment.

  • If Fuel or Solvents are recovered inside of a hangar, the vapor emissions created by the vacuum cleaner must be evacuated to the outside of the building. In order to do this the vacuum cleaners external port must be equipped with a hose attachment for venting to the outside.
  • The other option is a Granular Activated Carbon Adsorption System (also called Activated Charcoal). This is added at the exhaust port of the vacuum cleaner and will absorb any vapors that are emitted by the vacuum cleaner. This type of system is ideal for the removal of almost any organic compounds.

Tiger-Vac provides these two options when Fuels or Solvents need to be recovered, for example, in aircraft de-fueling and de-puddling requirements. It is absolutely essential that a Legally Certified Explosion Proof Vacuum Cleaner certified by a Nationally Recognized Testing Laboratory (NRTL) be used.

Please note the following: This line of vacuum cleaners complies with NFPA, NEC and OSHA standards set for flammable and combustible liquids  Class I, Division I locations. These vacuum cleaners also comply with 29 CFR 1910.307 and 29 CFR 1910.399. For more information please visit the OSHA website located at www.osha.gov.

Tiger-Vac sold its first vacuum cleaner in 1969. Having been in business for over 40 years, we have come to know our industry very well. Our customers demand a commitment to manufacturing and delivering quality vacuum cleaners that suit their various needs.

Being ISO 90001:2008 and CSA, ATEX, IECEx, NRTL (Nationally Recognized Testing Laboratory) worldwide certified, we have not only met these demands but exceeded them. We continuously strive to improve upon our existing products, as well as design new systems, to serve ever changing industries.

NUOVI MODELLI MONOFASE
ANTIDEFLAGRANTI/ANTI-INNESCO
ATEX CATEGORIA 2 G/D - ZONE 20 & 21
(DISPONIBILI SOLO DA TIGER-VAC)

ex-mat-logo

ce-mark 0081 ex_mark II 2 G/D Ex d IIB T4 Ex tD A21
IP65 - T135oC
LCIE 03 ATEX 6295

CD/EUR-36L EX (MRP)

con Sistema Manuale di Inversione Aria nel Filtro e Carrello con Motore Sospeso (CSMT)

cd-36-3CD-36-MRP-open

 

  • Cartuccia di Inversione Aria nel Filtro Conduttiva e Gonna
  • Totale superficie Cartuccia e Gonna: 28.5 ft² (26 500 cm²)
  • Motore Monofase TEFC Antideflagrante/Anti-Innesco.  115V & 230V.  50/60 Hz. 1-2 HP (1-1.5 kW)
  • Dimensioni: Altezza: 70” (1.78m)  Larghezza: 22” (56 cm)  Lunghezza: 31” (79 cm)  Peso” 218 lbs (99 kg)

 

CD/EUR-36L EX (MFS)

con Scuotifiltro Manuale e Carrello con Motore Sospeso (CSMT)

cd-36-mfsCD-36-MFS-open

 

  • Filtro Principale Conduttivo rivestito in Teflon Polyester Media (H13)
  • Totale superficie del Filtro Principale:  ft² (   cm²)
  • Motore Monofase TEFC Antideflagrante/Anti-Innesco.  115V & 230V.  50/60 Hz. 1-2 HP (1-1.5 kW)
  • Dimensioni: Altezza: 70” (1.78m)  Larghezza: 22” (56 cm)  Lunghezza: 31” (79 cm)  Peso” 218 lbs (99 kg)

Modelli Tri-Fase Associati

CD/EUR-50L EX DT (Modelli MRP & MFS)

CD-EUR-50L-MRP CD-EUR-55L-MFS CD-EUR-50L-MRP-alloff

Mostrato il modello MRP con serbatoio sganciato

  • Cartuccia di Inversione Aria nel Filtro con Gonna
  • Totale superficie Cartuccia di Invesione Aria SD* e Gonna: 19.1 ft² (17 700 cm²)
  • Motore Tri-Fase (TEFC) a servizio continuo.· 230/400/460/575 volt, 50/60 Hz, 5 HP (4 kW)


Nuovo Aspiratore Monofase EUR-25L DT (MFS)

  • A Dissipazione Statica
  • ATEX Categoria 3 Zona 22
  • Monofase, 115 e 230 Volt
CD-EUR-25L-MFS-SS_WHITE CD-EUR-25L-MFS-SS_WHITE-tank-off_WxCvQr CD-EUR-25L-MFS-SS_WHITE-all-off_kVJg0g
EUR-25L DT (MFS) Serbatoio di recupero amovibile (DT) Camera Filtro amovibile
  • Scuotifiltro Manuale, Teflon laminato (PTFE) supporto in poliestere (H13)
  • Include filtro HEPA (H14) ed accessori SD*
  • Capacità di Recupero di 6,5 gal (38l)
  • Progettato per la pulizia generale in Zona 22
  • Per applicazioni a servizio continuo, turbina (TEFC) disponibile monofase e trifase

SD* - A Dissipazione Statica

Nuovo Aspiratore per Farmaceutico EMI-1000


EMI-1000-POLY1Tiger-Vac è lieta di presentare la nuova serie di Aspiratori per Camere Bianche progettata per le industrie farmaceutiche.

La nostra Serie EMI-1000 è disponibile in Acciaio Inox o con sistema di contenimento sicuro.